Filter Results By:

Products

Applications

Manufacturers

Showing results: 586 - 600 of 666 items found.

  • Signal Injectors

    Core Technology Group

    Ideal high performance, low noise compliment to your Circuit Sleuth Frequency Response Analyzer. An injection transformer is used to couple an excitation signal from a frequency source into the feedback loop of a control system. This allows loop gain and phase vs. frequency to be measured, with the loop closed, thus characterizing the stability of the system.

  • Voice/Audio Quality Analyzer

    OPERA™ - OPTICOM GmbH

    The OPERA™ Voice/Audio Quality Analyzer represents the latest developments to objectively evaluate and assure the quality of compressed voice and wide-band audio signals, based on modeling the human ear. With OPERA you can achieve a comprehensive analysis of the end-to-end quality of today's and next generation networks, such as VoIP, VoDSL, VoATM, ISDN, GSM, POTS, from the caller to the callee. Also, you can test the audio quality of compression formats such as MP3, AAC, AC3, Microsoft Windows Media, from the studio source to the receiver, or from the server to the client.

  • DCA-M Sampling Oscilloscopes

    Keysight Technologies

    Built on Keysight's digital communication analyzer (DCA) technology, the DCA-M family is recognized as the industry standard for verifying optical transmitter compliance to communications standards. With single to quad optical AND electrical channels in a compact form factor, the DCA-M is ideal for both manufacturing and RND applications. Analyze both multi-mode and single-mode signals with the low-noise, high-sensitivity calibrated reference receivers. The variety of models along with the supporting software and compliance applications ensure you can measure with high precision, whether you analyze electrical or optical devices.

  • PXI-2547, 2.7 GHz, 50 Ω, 8x1 PXI RF Multiplexer Switch Module

    778572-47 - NI

    2.7 GHz, 50 Ω, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2547 is an RF signal multiplexer switch module. The higher channel count of the PXI‑2547 makes it ideal for test systems that require the switching of a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXIe-2748, 3 GHz, 16x1 PXI RF Multiplexer Switch Module

    780587-48 - NI

    PXIe, 3 GHz, 16x1 PXI RF Multiplexer Switch Module—The PXIe‑2748 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 3 GHz in production test applications. The high channel count of the PXIe‑2748 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.

  • PXIe-2746, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module

    780587-46 - NI

    PXIe, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module—The PXIe‑2746 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2746 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.

  • PXIe-2747, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module

    780587-47 - NI

    PXIe, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module—The PXIe‑2747 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2747 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.

  • PXI-2540, 350 MHz, 8x9 PXI RF Matrix Switch Module

    778572-40 - NI

    350 MHz, 8x9 PXI RF Matrix Switch Module—The PXI‑2540 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2540 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers.

  • Talon 6 GHz RF/IF Sentinel Intelligent Signal Scanning Rackmount Recorder

    Talon RTS 2620 - Pentek, Inc.

    - Search and capture system using Sentinel™ Intelligent Signal Scanner- Captures RF signals up to 6 GHz- Capture and scan bandwidths up to 40 MHz- 30 GHz/sec scan rate- Selectable threshold triggered or manual record modes- 16-bit A/D with 75 dB SNR & 87 dB SFDR- Built-in DDC with selectable decimation range from 2 to 65,536- Built-in DUC with selectable interpolation range from 2 to 65,536- 3U to 6U 19-inch rackmount server chassis with hot-swappable HDDs- Storage capabilities to 192 TB- RAID levels of 0, 5, and 6- Windows® workstation with Intel Core™ i7 processor- Optional RF upconversion- SystemFlow® GUI with virtual Oscilloscope, Spectrum Analyzer and Spectrogram displays

  • Communication Data Logger

    LE-270A - LINEEYE Co., Ltd.

    LE-270A is a Communication Data Logger, which records CAN/LIN communication logs in the SD/SDHC card for long hours. Using with a PC, it performs as a CAN/LIN protocol analyzer, and monitors data on the PC at real time (Line Monitor). Using without a PC, it performs as the CAN/LIN data logger, and saves data in the SD/SDHC card. It has two High-speed CAN transceivers, two Low-speed CAN transceivers and two LIN (TJA1020) transceivers. It monitors two channels of CAN or LIN, or one CAN and one LIN transceivers. In addition, four channels of Analog/Digital signals can be recorded.

  • Distributed Polarization Crosstalk Analyzer

    PXA-1000 - General Photonics Corp.

    The PXA-1000 Distributed Polarization Crosstalk (X-Talk) Analyzer is an enhanced white light interferometer that measures space-resolved stress by analyzing stress-induced polarization cross-coupling along a length of polarization maintaining (PM) fiber. The patented design eliminates strong zero-order interference and reduces the multi-coupling interference common in traditional white light interferometers, both of which can cause “ghost” peaks in the measured signal. The removal of the “ghost” peaks enables the PXA-1000 to unambiguously identify the magnitudes and locations of actual x-talk peaks, resulting in higher measurement sensitivity, higher dynamic range, and higher spatial measurement accuracy.

  • RF Explorer Spectrum Analyzers

    RF Explorer

    With so many different RF application fields, budget ranges and specific needs, it is an art to design the best possible match for everyone's needs with best quality and limited cost. We are delighted to offer a broad product range of tools, adjusted over more than 10 years of team dedicated R&D, careful listening to customer needs and feedback, and strong research on the latest technologies.Listed below you can find our current offering for RF Explorer models, including Spectrum Analyzers, Signal Generators, Expansion and IoT Modules and accessories.

  • PXI-2557, 2.5 GHz, 75 Ω, 8x1 PXI RF Multiplexer Switch Module

    778572-57 - NI

    2.5 GHz, 75 Ω, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2557 is an RF signal multiplexer switch module. The higher channel count of the PXI‑2557 makes it ideal for test systems that require the switching of a large number of video RF signals, such as switching several video tuners under test to a single channel on the RF analyzer. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • - Optical / RF Converter

    OPT 80 - Unaohm Start S.r.l.

    Calibrated measurement of the optical power of satellite and terrestrial TV signals distributed in optical fiber Calculation of optical signal losses on distribution Measurement of digital parameters (BER - MER - NM etc.) of optical signals converted into RF Visualization of optical carriers in RF Field Metric Spectrum Analyzer Power Meter Optical Field Meter Display Optical RF Power Supply Line Link Meter (LNB power supply ) Optical LNB power supply 13V 500mA with short circuit and overload managementAcquisition of optical measurements using the field meter Data Logger Option: certification of the OPT80 calibration and optical power measurements

  • Digital Digitizer

    MOS2 - Holding Informtest

    Mezzanine module (mezzanine) MOS2 is designed to convert instantaneous voltage values ​​of an electrical signal into a digital code, measure instantaneous voltage values. The mezzanine is intended for use in HF and microwave systems as a terminal device for digitizing intermediate frequency signals up to 200 MHz. Together with the frequency converter DOWNCONVERTER 10 GHz LXI manufactured by the holding "Informtest" MOS2 under the control of the common software shell ACM2 makes up a synthetic instrument - spectrum analyzer, a ready-made solution for testing microwave devices and radio reception channels.

Get Help